<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-22 05-19-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
90.50 MHz 5/5, 39 dBuV R-HK
Pilot RDS Phase Difference
6.4 kHz 3.0 kHz 68 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
10 kHz 44 kHz 18208 0,1043
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,0 dBr -0,30 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-HK " 280A 9 (Varied) 1 0 1 1 5:19, 22.05.2026
RT
"MONIKA ABSOLONOVA & DAVID DEYL - BUDU TU STAT "
AF EON
95.3, 96.5 MHz -
FM Scope Max at: 44 kHz MIN: 10 kHz % above 77 kHz: 0,1043 Acquired: 2026/05/22 5:19:44 Total samples: 18208 Equivalent time: 0:15:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,1 dBr MIN: -1,0 dBr AVE: -0,30 dBr % above 0,2 dBr: 0,0 Last value: -0,3 dBr (2026/05/22 5:19:43) 05:06 05:08 05:10 05:12 05:14 05:16 05:18 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality